MILWAUKEE Mi170 Combined logging with GLP EC/TDS/NaCl/Temp bench meter; range: EC 0.00 to 29.99 mS/cm; 30.0

  • Combined logging with GLP EC/TDS/NaCl/Temp bench meter; range: EC 0.00 to 29.99 mS/cm; 30.0
  • Model : Mi170
  • Code :

  • Brand : MILWAUKEE
RFQ

Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter Mi170 measures 4 different parameters - EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 or USB port.

SPECIFICATIONS EC Range : 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual Conductivity* TDS Range : 0.00 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.5 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor) NaCl Range : 0.0 to 400.0% Temp Range : -20.0 to 120.0°C / -4.0 to 248.0°F EC Resolution : 0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm; 0.01 mS/cm; 0.1 mS/cm TDS Resolution : 0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l NaCl Resolution : 0.1% Temp Resolution : 0.1°C / 0.1 °F EC Accuracy : ±1% of reading ±(0.05 µS/cm ro 1 digit) TDS Accuracy : ±1% of reading ±(0.03 mg/l or 1 digit) NaCl Accuracy : ±1% of reading Temp Accuracy : ±0.4°C / ±0.8°F EC Calibration : 1 point slope calibration with 6 memorized solutions (84.0 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) NaCl Calibration : 1 point, with MA9066 calibration solution Temp Calibration : 2 points, 0 to 50°C / 32 to 12 °F Temp. Compensation : automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°F Temp. Coefficient : selectable from 0.00 to 6.00%/°C (EC and TDS only) Probe : MA813D/1 4-ring probe with built-in temperature sensor (included) TDS Factor : 0.40 to 0.80 (default value is 0.50) Log on Demand : up to 50 samples on each range (EC, TDS, NaCl) GLP : last EC, NaCl calibration data PC Interface : RS232 / USB Opto-isolated Environment : 0 to 50°C / 32 to 122°F; max RH 95% Power supply: 12 VDC power adapter (included) Dimensions : 230 x 160 x 95 mm Weight : 0.9 kg